astarnes1

/Andy Starnes

About Andy Starnes

This author has not yet filled in any details.
So far Andy Starnes has created 27 blog entries.

Watch out for Mode Confusion

2017-10-10T08:40:31-04:00

Thermal Imaging Mode Confusion:   Firefighters need to be aware of when the camera switches modes and the color ranges associated with it. TIC's have modes based upon sensitivity which are typically high, medium, and low. For example, one camera switches from high sense mode at 350 degrees Fahrenheit while another switches to low sense mode at anything over 200 degrees Fahrenheit. How fast it changes especially if we are staying locked in on the same focal point should alert us to a rapid progression of the fire this impending flash-over. For example, a given reaction will increase its rate 100 [...]

Watch out for Mode Confusion2017-10-10T08:40:31-04:00

Enhanced Search Methodology

2017-10-09T17:36:12-04:00

The use of thermal imaging cameras has enhanced the firefighter’s overall effectiveness particularly in the area of searching for victims or downed firefighters. In the late 90’s several large and well-known fire departments were invited to participate in a study. They were given two identical search scenarios: one conducted without a TIC and one conducted with a TIC. The results were staggering. Without the use of a TIC the search crews missed the victims 60% of the time whereas they found the victim with the TIC while searching 99% of the time. In addition to this the total search time was [...]

Enhanced Search Methodology2017-10-09T17:36:12-04:00

The Power of Enhanced Stream Placement

2017-10-09T17:28:01-04:00

In our recent training at Ottawa Fire, Shawn Bloemker and I instructed firefighters on the value of enhanced stream placement. This is one of many concepts that Project Kill the Flashover advocates in our Tactical Thermal Imaging Program. The video above shows the stream being directed by the TIC at our training at Monroe Fire Department (video courtesy of a FLIR K65) In this short video below (video courtesy of Bullard LDX), one can see the moving convection heat currents over the firefighters head that are often missed due to zero visibility. This can be compared to being in [...]

The Power of Enhanced Stream Placement2017-10-09T17:28:01-04:00

TIC’s are NOT Thermometers? No Kidding?

2018-04-07T13:22:23-04:00

Thermal Imaging Training Series: Tactical TIC use is not a thermometer With the recent release of the UL Fire Attack Study, we have received numerous questions about the reliability of TIC use in the fire environment. After reviewing the very short section on thermal imaging in their report there are several common statements that were already known in regards to thermal imaging that firefighters may not been aware of it but our curriculum teaches. The following quote comes from page 167 of the report: “Further, the sensors in the thermal imagers are designed for a range of wavelengths which allow them [...]

TIC’s are NOT Thermometers? No Kidding?2018-04-07T13:22:23-04:00

The Danger of the Spot Temperature

2017-09-23T21:46:53-04:00

In traveling and teaching our curriculum, we continue to see a dangerous trend in TIC use. Many firefighters only read the numerical temperature reading in the lower right corner of the view finder otherwise known as the "spot temperature" or direct temperature measurement. This is a very dangerous issue. Here is why: The spot temperature is a numerical representation of the average of a certain amount of pixels within the focal point (or cross hairs) at a preset distance set by the manufacturer. This spot temperature is NOT an accurate representation of the overall environment. As you can see in the [...]

The Danger of the Spot Temperature2017-09-23T21:46:53-04:00

How Do Firefighters Measure Heat?

2017-09-20T23:03:15-04:00

How Do Firefighters Measure Heat? Today’s thermal environment of higher heat release fuels demands a diagnostic tool that allows firefighters to prevent thermal insult, identify and locate the fire’s severity, and locate any victims or firefighters in danger more quickly than ever before. And those who advocate that firefighters should wait to feel the heat to indicate their level of safety should read and remember the following: The equipment we use to protect ourselves or work in these superheated environments are designed to operate at only a Thermal Class III for a maximum of five minutes which equates to 500 degrees [...]

How Do Firefighters Measure Heat?2017-09-20T23:03:15-04:00

Ever read the instructions on your turnout gear?

2017-09-20T22:40:12-04:00

Ever read the instructions on your turnout gear? The following quotes come directly from Fire & Emergency Manufacturers and Services Association (FEMSA) User Information Guide which comes with every brand-new set of Firefighter Protective Garments. The following information should be read and understood by all firefighters.  “If your protective ensemble is exposed to radiant, convective, or conductive heat, you may be burned underneath with no warning and no sign of damage to the protective ensemble. Be constantly alert to the possibility of exposure to radiant, convective, or conductive heat and other hazards” (FEMSA User Guide p. 2-4). “Burns are a [...]

Ever read the instructions on your turnout gear?2017-09-20T22:40:12-04:00